DEVICE: TYSHAK® (04046964331268)
Device Identifier (DI) Information
TYSHAK®
610629
In Commercial Distribution
610629
B BRAUN INTERVENTIONAL SYSTEMS, INC
610629
In Commercial Distribution
610629
B BRAUN INTERVENTIONAL SYSTEMS, INC
PCD059 SPECIAL BALLOON CATH 18MM 10CM
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
Yes | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
17453 | Cardiac valvuloplasty catheter |
A sterile flexible tube with an inflatable balloon designed to perform plastic or restorative surgery on a cardiac valve, i.e., for the dilatation of atrioventricular, aortic, and pulmonary trunk valves. It is typically used for the percutaneous dilatation of commissural fusion in stenotic mitral valves and for annular, cuspal, and calcific nodular fractures, to improve cuspal mobility in adult calcific aortic stenosis, and for leaflet tearing in pulmonic valve stenosis. It may also be used for percutaneous balloon pericardiotomy. This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
LIT | Catheter, angioplasty, peripheral, transluminal |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K931009 | 000 |
K991977 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Special Storage Condition, Specify: Keep away from sunlight |
Special Storage Condition, Specify: |
Special Storage Condition, Specify: Store at room temp |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
5e830ab2-9d57-4dec-b5fd-bdf5155136db
September 07, 2023
5
August 09, 2016
September 07, 2023
5
August 09, 2016
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(877)836-2228
GUDID.BBMUS_Service@bbraun.com
GUDID.BBMUS_Service@bbraun.com