DEVICE: Anti-TCRa/b-PE (Clone REA652) (04049934133909)

Device Identifier (DI) Information

Anti-TCRa/b-PE (Clone REA652)
170-081-069
In Commercial Distribution

Miltenyi Biotec B.V. & Co. KG
04049934133909
GS1

1
342920388 *Terms of Use
REA652 recognizes the human alpha/beta T cell receptor (TCR). The T cell receptor is a heterodimer composed of two transmembrane glycoprotein chains, alpha and beta. In 95% of T cells the TCR consists of an alpha and beta chain, whereas in 5% of T cells it has gamma and delta chains. Alpha and beta chains are members of the Ig superfamily and consist of a constant and a polymorphic variable region. The variable region of the TCRalpha/beta is involved in recognition of antigenic peptides presented by the MHC complex of antigen-presenting cells. Additional information: Clone REA652 displays negligible binding to Fc receptors.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
No
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
64705 Assay development analyte-specific reagent IVD
An antibody, specific receptor protein, ligand, nucleic acid sequence (e.g., primer, probe) or similar reagent, which through specific binding or chemical reaction with an intended target, is used to identify or quantify a chemical substance in a biological specimen for the development of a laboratory developed test (LDT) or commercial in vitro diagnostic medical device (IVD). Commonly referred to as an analyte specific reagent (ASR), it is neither labelled with instructions for use nor diagnostic or performance claims.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
MVU Reagents, Specific, Analyte
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
Yes CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Special Storage Condition, Specify: 2 - 8 °C Protected from light.
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

c29eff9b-2afd-4d69-9a91-16016875492d
April 05, 2021
1
March 26, 2021
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
Yes
Yes
Yes
No CLOSE

Customer Contact

[?]
800-367-6227
technicalsupportUS@miltenyi.com
CLOSE