DEVICE: CD94-APC (04049934134265)
Device Identifier (DI) Information
CD94-APC
170-081-033
In Commercial Distribution
Miltenyi Biotec B.V. & Co. KG
170-081-033
In Commercial Distribution
Miltenyi Biotec B.V. & Co. KG
REA113 recognizes CD94, an approximately 45 kDa, single pass, type II transmembrane protein, which belongs to C-type lectin superfamily. CD94 associates covalently with NKG2 family members and forms disulfide-bonded heterodimers. CD94-NKG2 receptors bind HLA-E, the non-classical MHC class Ib molecule. Depending on the associated NKG2 member, CD94-NKG2 heterodimer transmits either activating or inhibitory signal. For example, via immunoreceptor tyrosine–based inhibitory motifs (ITIMs) containing NKG2A, CD94-NKG2A heterodimers inhibit NK cell cytotoxicity. Besides NK cells, expression of CD94-NKG2 heterodimers is also shown on NK-T cells and a small percentage of CD8 cells in mice, where the crosslinking of CD94-NKG2 was shown to reduce the level of spontaneous apoptosis.
Additional Information: Clone REA113 displays negligible binding to Fc receptors.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
No | |
No | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
64705 | Assay development analyte-specific reagent IVD |
An antibody, specific receptor protein, ligand, nucleic acid sequence (e.g., primer, probe) or similar reagent, which through specific binding or chemical reaction with an intended target, is used to identify or quantify a chemical substance in a biological specimen for the development of a laboratory developed test (LDT) or commercial in vitro diagnostic medical device (IVD). Commonly referred to as an analyte specific reagent (ASR), it is neither labelled with instructions for use nor diagnostic or performance claims.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
MVU | Reagents, Specific, Analyte |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Special Storage Condition, Specify: 2 - 8 °C Protected from light. |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
883285aa-4234-4b7f-ad06-a178c07fe593
April 05, 2021
1
March 26, 2021
April 05, 2021
1
March 26, 2021
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
800-367-6227
technicalsupportUS@miltenyi.com
technicalsupportUS@miltenyi.com