DEVICE: BEE Cage (04251631414742)
Device Identifier (DI) Information
BEE Cage
BEE Cage cervical 5 x 14 mm 4° S
In Commercial Distribution
B514S
NGMedical GmbH
BEE Cage cervical 5 x 14 mm 4° S
In Commercial Distribution
B514S
NGMedical GmbH
BEE Cages were especially adapted to the local anatomy to secure the surgical outcome at the best. The caudal side is flat, the cranial side is domed and the implant is formed conically from anterior to posterior. In the lateral view, the implant has a slightly lordotic form. The cage disposes of 4 pins on both bone facing surfaces, which serve the primary fixation. BEE implants are made of titanium alloy (Ti6Al4V) according to ASTM F 3001. BEE Cages are produced with selective laser melting (SLM) technique. It is not allowed to use BEE implants in contact with components of other manufacturers with the exception of bone graft substitutes or fillers.
Device Characteristics
MR Unsafe | |
No | |
No | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
38161 | Metallic spinal interbody fusion cage |
A device intended to be implanted into the space of an intervertebral disc that has been partially or totally removed during surgery in order to allow bone fusion between two contiguous vertebral bodies, typically in the treatment of degenerative disc disease (DDD). It is in the form of a hollow, porous, threaded and/or fenestrated cylindrical or geometrical device made of metal [e.g., titanium (Ti)] that provides mechanical stability and sufficient space for therapeutic spinal bone fusion to occur; bone graft is typically used to help with osseointegration. Fixation screws and devices associated with implantation may be included with the device.
|
Active | true |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
ODP | Intervertebral Fusion Device With Bone Graft, Cervical |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K200429 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Temperature: between -5 and 25 Degrees Celsius |
Clinically Relevant Size
[?]Size Type Text |
---|
Device Size Text, specify: 10x16 mm 8° |
Device Record Status
175884a4-2dcb-4070-896f-217e4dc22509
January 24, 2024
1
January 16, 2024
January 24, 2024
1
January 16, 2024
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
No Customer Contact currently defined