DEVICE: ROTEM® (04260160470044)

Device Identifier (DI) Information

ROTEM®
in-tem®
In Commercial Distribution
503-02-US
Tem Innovations GmbH
04260160470044
GS1

10
506692297 *Terms of Use
The ROTEM® delta is designed for in-vitro diagnostic use by professionals in a laboratory environment. The ROTEM® delta is intended to be used to provide a qualitative and quantitative indication of the coagulation state of a blood sample. For this purpose the ROTEM® delta records the clot firmness changes in a sample of citrated whole blood as the sample clots, retracts and lyses in real time. The analyzer output consists of a qualitative graphical representation (mirrored coagulation curve - clot firmness over time) and several defined numerical parameters describing the curve quantitatively. The in-tem® assay is a semi-quantitative in vitro diagnostic assay used to monitor the coagulation process via the intrinsic pathway in citrated whole blood specimens on the ROTEM® delta. Clotting characteristics are described by the functional parameters Clotting Time (CT), Speed of Clot Formation (CFT and alpha angle), Clot Firmness (A20/MCF) and Clot Lysis (LOT, ML, LI(x)).
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
No
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
30595 Multiple coagulation factor IVD, reagent
A substance or reactant intended to be used together with a parent IVD to perform a specific function in an assay that is used for the qualitative and/or quantitative determination of one or multiple coagulation factors, coagulation intermediates and/or their activated components in a clinical specimen.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
GGN Plasma, Coagulation Control
JPA System, Multipurpose For In Vitro Coagulation Studies
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K083842 000
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Temperature: between 2 and 8 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

57836af2-4a79-400c-9a19-ac60af788a1a
July 06, 2018
3
September 16, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: 04260160470464 CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
No Customer Contact currently defined
CLOSE