DEVICE: ROTEM® (04260160470099)
Device Identifier (DI) Information
ROTEM®
star-tem® 20
In Commercial Distribution
503-10-US
Tem Innovations GmbH
star-tem® 20
In Commercial Distribution
503-10-US
Tem Innovations GmbH
The ROTEM® delta is designed for in-vitro diagnostic use by professionals in a laboratory environ-ment. The ROTEM® delta is intended to be used to provide a qualitative and quantitative indication of the coagulation state of a blood sample. For this purpose the ROTEM® delta records the clot firmness changes in a sample of citrated whole blood as the sample clots, retracts and lyses in real time. The analyzer output consists of a qualitative graphical representation (mirrored coagulation curve – clot firmness over time) and several defined numerical parameters describing the curve quantitatively.
The star-tem® reagent is intended for use as recalcification reagent in the NATEM and INTEM assay on the ROTEM® delta. The corresponding assays are described in the NATEM assay application sheet and in the Instructions for Use of the in-tem® reagent (REF 503-02-US), resp.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
No | |
No | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
30595 | Multiple coagulation factor IVD, reagent |
A substance or reactant intended to be used together with a parent IVD to perform a specific function in an assay that is used for the qualitative and/or quantitative determination of one or multiple coagulation factors, coagulation intermediates and/or their activated components in a clinical specimen.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
GGN | Plasma, Coagulation Control |
JPA | System, Multipurpose For In Vitro Coagulation Studies |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K083842 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Temperature: between 2 and 8 Degrees Celsius |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
27b853b4-9363-4006-96a8-6984a5a0d86b
July 06, 2018
3
September 16, 2016
July 06, 2018
3
September 16, 2016
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
04260160470518
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
No Customer Contact currently defined