DEVICE: ROTEM® (04260160470372)

Device Identifier (DI) Information

ROTEM®
sigma
In Commercial Distribution
211000
Tem Innovations GmbH
04260160470372
GS1

1
506692297 *Terms of Use
The ROTEM sigma is an in vitro diagnostic (IVD) whole blood hemostasis system intended for use in the evaluation of coagulopathies in Point of Care (POC) or laboratory settings. It uses rotational thromboelastometry to provide semiquantitative information about the coagulation state of a blood sample. The ROTEM sigma system records the kinetic changes in a sample of 3.2% citrated whole blood during clot formation, as well as when the sample clot retracts and/or lyses. Several parameters are measured and reported for this purpose. The graphical presentation reflects the various physiological results, which describe the interaction between coagulation factors and inhibitors, fibrinogen, platelets, and the fibrinolysis system. Additionally, the effect of certain drugs influencing hemostasis, in particular some anticoagulants (e.g. heparin), can be detected.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
56689 Coagulation analyser IVD, laboratory
An electrically-powered automated or semi-automated laboratory instrument intended to be used for the qualitative and/or quantitative in vitro determination of one or multiple coagulation components involved in haemostasis in a clinical specimen [e.g., performs tests such as prothrombin time (PT), partial thromboplastin time (PTT)]. Analyser design may incorporate spectrophotometry, turbidimetry, nephelometry, electrometry, electromagnetic and/or mechanical means of clot formation or end point detection.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
JPA System, Multipurpose For In Vitro Coagulation Studies
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K201440 000
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

14bf03af-8f48-44a6-b28a-3ea43b897da5
October 12, 2022
1
October 04, 2022
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
Yes
No CLOSE

Customer Contact

[?]
No Customer Contact currently defined
CLOSE