DEVICE: Coag Dissector (04260206311027)

Device Identifier (DI) Information

Coag Dissector
165 cm
In Commercial Distribution
200.50
Ovesco Endoscopy AG
04260206311027
GS1

1
344007369 *Terms of Use
04260206310341
The Coag Dissector is a monopolar electrosurgical instrument for dissection and hemostasis using flexible endoscopes • tip design inspired by laparoscopic surgical instruments • branches for blunt dissection of tissue • good coagulation capabilities between branches • rotatable flexible shaft for precise alignment of tip orientation • curved grasper for precise targeting of the tissue • teeth provide secure grasping of the bleeding area
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
Yes
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
58039 Endoscopic electrosurgical handpiece/electrode, monopolar, single-use
An electrosurgical device consisting of a handpiece with mechanical and/or electrical controls, and a monopolar electrode, intended to deliver a current from a system generator directly to tissues for cutting/coagulation/ablation during endoscopic (including laparoscopic, arthroscopic) surgery. It includes a long thin electrode connected to the handpiece and requires a patient contact return electrode; it may include a suction/irrigation lumen and may feature a magnetic guidance sensor for electromagnetic tracking. It is available in a variety of forms (e.g., forceps or snare with ring handles, rigid probe) and may also be designed to mechanically cut tissues. This is a single-use device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
KGE Forceps, Biopsy, Electric
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K141794 000
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Temperature: between 10 and 35 Degrees Celsius
Storage Environment Humidity: between 15 and 70 Percent (%) Relative Humidity
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Device Size Text, specify: working channel diameter 2.8 mm
Device Size Text, specify: working length 165 cm
CLOSE

Device Record Status

de561b9c-30e5-418c-9f76-a06abfaca509
August 07, 2024
5
July 05, 2018
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
Yes
No CLOSE

Customer Contact

[?]
+19196519449
customerservice@ovesco-usa.com
+49707196528160
service@ovesco.com
CLOSE