DEVICE: FUJIFILM (04547410079180)
Device Identifier (DI) Information
FUJIFILM
ST-05B
In Commercial Distribution
FUJIFILM CORPORATION
ST-05B
In Commercial Distribution
FUJIFILM CORPORATION
This product is the balloon setting tool used in combination with our endoscope and balloon in medical facilities.
Do not use this product for any other purpose.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
66031 | Endoscope balloon positioner, single-use |
A hand-held manual device exclusively intended to mount an endoscope balloon or endoscope balloon connector (typically a flexible rubber band) onto the distal end of an endoscope prior to balloon inflation; the balloon and connector are not included. It is available in various designs (e.g., tweezer-, pistol- or cone-like with pointed tip). This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
FFY | Adaptor, bulbs, miscellaneous, for endoscope |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Temperature: between -20 and 60 Degrees Celsius |
Storage Environment Atmospheric Pressure: between 70 and 106 KiloPascal |
Storage Environment Humidity: between 10 and 85 Percent (%) Relative Humidity |
Handling Environment Temperature: between 10 and 40 Degrees Celsius |
Handling Environment Humidity: between 30 and 85 Percent (%) Relative Humidity |
Handling Environment Atmospheric Pressure: between 70 and 106 KiloPascal |
Special Storage Condition, Specify: There must be no condensation. |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
06ddb1e8-85b5-41e1-af4a-9a5908f14943
June 10, 2024
2
October 07, 2022
June 10, 2024
2
October 07, 2022
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
24547410079184 | 1 | 04547410079180 | In Commercial Distribution | Box |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
84547410079186
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+018002728465
xxx@xxx.xxx
xxx@xxx.xxx