DEVICE: DR-ID 1200MC (04547410288995)

Device Identifier (DI) Information

DR-ID 1200MC
DR-ID 1200 MC SOFT E
In Commercial Distribution

FUJIFILM CORPORATION
04547410288995
GS1

1
713565195 *Terms of Use
A personal computer used for controlling the flat panel sensor and performing image processing.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
No
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
61109 Diagnostic x-ray digital imaging conversion system
An assembly of medical devices designed to convert an existing analogue x-ray system to digital (i.e., retrofit) through the acquisition and processing of digital images using existing analogue x-ray system components. As a system it consists of both: 1) a filmless cassette-size digital detector (e.g., indirect flat panel detector); and 2) additional processing/viewing hardware [e.g., a central processing unit (CPU) with integrated software and a monitor]. Following acquisition the system is intended to also process, view, and/or store patient images as part of picture archiving and communication. It does not contain the controls for the direct operation of an x-ray imaging system.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
MQB Solid state x-ray imager (flat panel/digital imager)
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K142003 000
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Handling Environment Temperature: between 15 and 30 Degrees Celsius
Storage Environment Atmospheric Pressure: between 70 and 106 KiloPascal
Handling Environment Humidity: between 15 and 80 Percent (%) Relative Humidity
Handling Environment Atmospheric Pressure: between 70 and 106 KiloPascal
Storage Environment Humidity: between 10 and 90 Percent (%) Relative Humidity
Storage Environment Temperature: between -30 and 50 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

b629b2f0-40c1-453c-aec1-b957d7adb458
December 11, 2023
4
September 16, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
Yes
No CLOSE

Customer Contact

[?]
+018002728465
xxx@xxx.xxx
CLOSE