DEVICE: FUJIFILM (04547410313321)

Device Identifier (DI) Information

FUJIFILM
AW-602
In Commercial Distribution

FUJIFILM CORPORATION
04547410313321
GS1

1
713565195 *Terms of Use
This product is a medical device that is attached to a FUJIFILM gastrointestinal endoscope in order to jet air or water as well as to dischange water from the balloon. Do not use this product for any other purpose.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
61792 Endoscope air/water valve, reusable
A device intended to be fitted to an endoscope air/water channel to enable the operator to control inflow of medical gases [i.e., air, carbon dioxide (CO2)] and/or water whilst preventing backflow. It is in the form of an attachable valve with one or more settings such as closed, insufflation (allowing air/gas in), and irrigation/rinse (allowing water in). This is a reusable device intended to be reprocessed prior to use.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
FFY Adaptor, bulbs, miscellaneous, for endoscope
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
Yes CLOSE

Sterilization

No
Yes
Sterilization Method [?]
High-level Disinfectant
Ethylene Oxide
Moist Heat or Steam Sterilization
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Temperature: between -20 and 60 Degrees Celsius
Storage Environment Atmospheric Pressure: between 70 and 106 KiloPascal
Storage Environment Humidity: between 10 and 85 Percent (%) Relative Humidity
Special Storage Condition, Specify: There must be no condensation.
Handling Environment Temperature: between 10 and 40 Degrees Celsius
Handling Environment Humidity: between 30 and 85 Percent (%) Relative Humidity
Handling Environment Atmospheric Pressure: between 70 and 106 KiloPascal
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

3ff84d7a-f74a-4a44-8127-34fe228eb1a6
July 25, 2024
3
October 07, 2022
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
24547410313325 1 04547410313321 In Commercial Distribution Box
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
Yes
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
No
Yes
No CLOSE

Customer Contact

[?]
+018002728465
xxx@xxx.xxx