DEVICE: FUJIFILM (04547410342741)

Device Identifier (DI) Information

FUJIFILM
SP-900
In Commercial Distribution

FUJIFILM CORPORATION
04547410342741
GS1

1
713565195 *Terms of Use
The FUJIFILM ultrasonic processor SP-900 is intended to be used in combination with FUJIFILM Ultrasonic Probe, video processor, light source, monitor, recorder, and various peripheral devices. The product is intended to provide ultrasonic images of the gastrointestinal tract, biliary and pancreatic ducts and surrounding organs, airways and tracheobronchial tree for observation, recording and to aid in diagnosis during endoscopic evaluation. Modes of Operation: B-mode
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
40761 General-purpose ultrasound imaging system
A stationary or mobile (e.g., on wheels) assembly of devices designed to collect, display, and analyse ultrasound images during a variety of extracorporeal and/or intracorporeal (endosonography or endoscopic) ultrasound imaging procedures (e.g., cardiac, OB/GYN, endoscopy, breast, prostate, vascular, and intra-surgical imaging). It consists of a mains (AC-powered) data processing unit with integrated software and a monitor. It is typically presented as a mobile assembly which may support a wide variety of transducers and related application software packages; an ultrasound transducer(s) may be included.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
IYO System, Imaging, Pulsed Echo, Ultrasonic
ODG Endoscopic ultrasound system, gastroenterology-urology
ITX Transducer, Ultrasonic, Diagnostic
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K214089 000
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Atmospheric Pressure: between 70 and 106 KiloPascal
Handling Environment Atmospheric Pressure: between 70 and 106 KiloPascal
Handling Environment Humidity: between 30 and 85 Percent (%) Relative Humidity
Handling Environment Temperature: between 10 and 40 Degrees Celsius
Storage Environment Humidity: between 10 and 90 Percent (%) Relative Humidity
Special Storage Condition, Specify: There must be no condensation.
Storage Environment Temperature: between -20 and 60 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

ab7f0569-5c8e-4efe-8e2d-7a3fe8740c11
June 07, 2024
6
February 23, 2018
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
Yes
No CLOSE