DEVICE: FUJIFILM (04547410438673)

Device Identifier (DI) Information

FUJIFILM
CA-617
In Commercial Distribution

FUJIFILM CORPORATION
04547410438673
GS1

1
713565195 *Terms of Use
This product is exclusively used for manual cleaning and manual disinfection of a FUJIFILM endoscope in medical facilities. Do not use this product for any other purpose.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
61723 Luminal device flushing tubing set, reusable
A collection of devices which includes connection tubing intended to be fitted to a luminal device (e.g., catheter, endoscope channel, ophthalmic handpiece) to assist flushing the device lumen during a medical/surgical procedure, and/or to assist the washing, disinfection and/or sterilization of the lumen. In addition to tubing, the set includes connectors/valves to allow appropriate fluids (e.g., sterilant, disinfectant) and gases to flow through the device lumen. It may be used in conjunction with a syringe, device washer/disinfector, and/or water tap. This is a reusable device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
FFY Adaptor, Bulbs, Miscellaneous, For Endoscope
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
Yes CLOSE

Sterilization

No
Yes
Sterilization Method [?]
High-level Disinfectant
Moist Heat or Steam Sterilization
Ethylene Oxide
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Atmospheric Pressure: between 70 and 106 KiloPascal
Handling Environment Atmospheric Pressure: between 70 and 106 KiloPascal
Storage Environment Temperature: between -20 and 60 Degrees Celsius
Handling Environment Temperature: between 10 and 40 Degrees Celsius
Storage Environment Humidity: between 10 and 85 Percent (%) Relative Humidity
Handling Environment Humidity: between 30 and 85 Percent (%) Relative Humidity
Special Storage Condition, Specify: There must be no condensation.
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

7d8ca84e-9ae5-4df3-9fa1-1f7144e634cd
June 07, 2024
3
May 31, 2021
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
24547410438677 1 04547410438673 In Commercial Distribution Box
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
No
Yes
No CLOSE

Customer Contact

[?]
+018002728465
xxx@xxx.xxx
CLOSE