DEVICE: FUJIFILM (04547410467284)
Device Identifier (DI) Information
FUJIFILM
BS-4
In Commercial Distribution
FUJIFILM CORPORATION
BS-4
In Commercial Distribution
FUJIFILM CORPORATION
This product is used in combination with FUTIFILM Double Balloon Endoscopes at medical facilities under the management of physicians. Being attached to the endoscope, this product is inserted into the digestive tract from the mouth or anus to stabilize the distal end of the endoscope to the digestive tract's mucous membrane. Do not use this product for any other purposes. This product is not intended for use for any neonates , infants or children
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
Yes | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
45712 | Gastrointestinal/biliary dilation balloon catheter, non-medicated |
A long, thin, flexible tube with an inflatable balloon at its distal tip intended to be used for gastrointestinal and/or biliary intraluminal dilation; it is typically used to endoscopically dilate strictures of the oesophagus, pylorus, colon and/or biliary tract. The balloon is inflated to its prescribed diameter to widen the affected passage of the tract. The device may consist of one or more lumen, may be of the fixed-wire or wire-guided type, and is not coated with a drug/pharmaceutical. This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
FDF | Colonoscope And Accessories, Flexible/Rigid |
FDA | Enteroscope And Accessories |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Special Storage Condition, Specify: Stored in a package box |
Handling Environment Temperature: between 10 and 40 Degrees Celsius |
Handling Environment Humidity: between 30 and 85 Percent (%) Relative Humidity |
Handling Environment Atmospheric Pressure: between 70 and 106 KiloPascal |
Special Storage Condition, Specify: There must be no condensation. |
Storage Environment Temperature: between -10 and 60 Degrees Celsius |
Storage Environment Atmospheric Pressure: between 70 and 106 KiloPascal |
Storage Environment Humidity: between 30 and 95 Percent (%) Relative Humidity |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
7b3b6cce-d619-438f-b67a-944e995dae09
December 23, 2024
3
February 06, 2023
December 23, 2024
3
February 06, 2023
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
14547410467281 | 10 | 04547410467284 | In Commercial Distribution | Box |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+018002728465
xxx@xxx.xxx
xxx@xxx.xxx