DEVICE: 3D Accuitomo XYZ Slice View Tomograph (04548213016341)

Device Identifier (DI) Information

3D Accuitomo XYZ Slice View Tomograph
MCT-1
In Commercial Distribution

J.MORITA MFG.CORP.
04548213016341
GS1

1
693811465 *Terms of Use
No description.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
61019 Cone beam computed tomography system, head/neck
A stationary assembly of mains electricity (AC-powered) devices intended to produce two- or three-dimensional (3-D) diagnostic digital x-ray images of the head/neck using cone beam computed tomography (CBCT). It consists of an x-ray source assembly, high-voltage generator, x-ray detector, processor, reconstruction software, and patient support device (e.g., seat, stabilizing bite block); the patient is typically scanned in an upright position by a rotating arm. It is typically intended for (but not limited to) dental and ear/nose/throat (ENT) applications.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
JAK System, X-Ray, Tomography, Computed
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K073695 000
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Handling Environment Temperature: between 10 and 30 Degrees Celsius
Handling Environment Humidity: between 30 and 75 Percent (%) Relative Humidity
Handling Environment Atmospheric Pressure: between 70 and 106 KiloPascal
Storage Environment Atmospheric Pressure: between 70 and 106 KiloPascal
Storage Environment Humidity: between 8 and 85 Percent (%) Relative Humidity
Storage Environment Temperature: between -5 and 43 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

9ee4e6ac-c590-4918-8377-3f5a6ca50532
March 30, 2020
1
March 21, 2020
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
Yes
No CLOSE

Customer Contact

[?]
No Customer Contact currently defined
CLOSE