DEVICE: HITACHI (04562122954655)

Device Identifier (DI) Information

HITACHI
UST-5293-5
Not in Commercial Distribution

HITACHI, LTD.
04562122954655
GS1
June 30, 2021
1
693002605 *Terms of Use
Probe
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. The copyright and database rights in the original GMDN materials are owned by The GMDN Agency Ltd 2005-2023. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
37891 Oesophageal ultrasound imaging transducer, reusable
An ultrasound imaging transducer assembly enclosed in a fluid-resistant, acoustically- and electrically-insulated housing, designed to be inserted and positioned in the oesophagus to obtain ultrasound images of the heart and/or to navigate devices requiring ultrasound guidance and placement (e.g., endoscopy equipment or needle biopsy equipment). Also known as an oesophageal endosonography probe or transducer, it is composed of either a single transducer element or an array of transducer elements, i.e., piezoelectric element(s), active element(s), or crystal(s), and associated damping, backing, and matching layer materials. This is a reusable device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
IYO System, Imaging, Pulsed Echo, Ultrasonic
ITX Transducer, Ultrasonic, Diagnostic
IYN System, Imaging, Pulsed Doppler, Ultrasonic
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Temperature: between -10 and 50 Degrees Celsius
Storage Environment Humidity: between 10 and 90 Percent (%) Relative Humidity
Storage Environment Atmospheric Pressure: between 70 and 106 KiloPascal
Handling Environment Temperature: between 10 and 40 Degrees Celsius
Handling Environment Humidity: between 30 and 75 Percent (%) Relative Humidity
Handling Environment Atmospheric Pressure: between 70 and 106 KiloPascal
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

2ea7d5f9-3158-4953-9c7e-2b5373b463d0
July 01, 2021
4
October 25, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
Yes
No CLOSE

Customer Contact

[?]
No Customer Contact currently defined
CLOSE