DEVICE: HITACHI (04562122957014)

Device Identifier (DI) Information

HITACHI
UST-9120
Not in Commercial Distribution

HITACHI, LTD.
04562122957014
GS1
June 30, 2021
1
693002605 *Terms of Use
Probe Compatible with waterproof cover
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
40770 Surgical ultrasound imaging transducer
A hand-held ultrasound imaging transducer assembly designed to be positioned within a surgical site for localized intraoperative imaging applications. It is sometimes referred to as a surgical probe or fingertip probe. It steers, focuses, and detects the ultrasound beam and resulting echoes either mechanically or electronically. This group of devices includes ultrasound imaging transducer assemblies used with A-mode, B-mode, M-mode, Doppler, colour Doppler (CD), and duplex (combination imaging, Doppler and/or colour flow) scanning capabilities. This is a reusable device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
IYO System, Imaging, Pulsed Echo, Ultrasonic
ITX Transducer, Ultrasonic, Diagnostic
IYN System, Imaging, Pulsed Doppler, Ultrasonic
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

No
Yes
Sterilization Method [?]
Liquid Chemical
Peracetic Acid
Hydrogen Peroxide
Ethylene Oxide
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Temperature: between -10 and 50 Degrees Celsius
Storage Environment Humidity: between 10 and 90 Percent (%) Relative Humidity
Storage Environment Atmospheric Pressure: between 70 and 106 KiloPascal
Handling Environment Temperature: between 10 and 40 Degrees Celsius
Handling Environment Humidity: between 30 and 75 Percent (%) Relative Humidity
Handling Environment Atmospheric Pressure: between 70 and 106 KiloPascal
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

6516f150-1a6b-4c87-9a71-71c9fa236960
July 02, 2021
6
September 13, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
Yes
No CLOSE

Customer Contact

[?]
No Customer Contact currently defined
CLOSE