DEVICE: Harbor Freight Tools (04710953421628)

Device Identifier (DI) Information

Harbor Freight Tools
58460
In Commercial Distribution

AVITA CORPORATION
04710953421628
GS1

1
658023275 *Terms of Use
The product automatically measures human begins Systolic, Diastolic blood pressure and pulse rate by oscillometric method. The measurement results are displayed on the LCD. Measurement position is at human being's wrist. The intended use of this over-the-counter device is for adults with wrist circumference ranging from 125 mm to 210 mm (Approx.4.9 ~ 8.3 inches) and for home use. When the device detects the appearance of irregular heartbeats such as atrial or ventricular premature beats during measurement, an indicated symbol will appear with measuring readings. This device is designed only for adults.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
No
Yes
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
16173 Automatic-inflation electronic sphygmomanometer, non-portable
An electrically-powered device designed to noninvasively measure blood pressure using a self-contained software program that regulates automatic arm-cuff inflation and measurement cycles. It typically displays current heart rate and mean arterial pressure in addition to systolic and diastolic blood pressures; it may have memory to store blood pressure values and may sound an alarm if blood pressure exceeds pre-set limits. This device is not designed to be portable and is typically used bedside.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
DXN System, Measurement, Blood-Pressure, Non-Invasive
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

640cc804-4fdf-45fa-9d60-50e61d5080c6
October 21, 2020
1
October 13, 2020
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
04710953421635 24 04710953421628 In Commercial Distribution Paper box
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
No
No
No CLOSE

Customer Contact

[?]
+886285121568
pin_fan@avita.com.tw
CLOSE