DEVICE: United Hip System, U-Motion II XPE Cup Liner (04712771503418)
Device Identifier (DI) Information
United Hip System, U-Motion II XPE Cup Liner
1406-3844
In Commercial Distribution
1406-3844
UNITED ORTHOPEDIC CORP.
1406-3844
In Commercial Distribution
1406-3844
UNITED ORTHOPEDIC CORP.
U-Motion II XPE Cup Liner, 0 DEG., I.D. 28mm, O.D. 44mm
Device Characteristics
| Labeling does not contain MRI Safety Information | |
| No | |
| No | |
| Yes | |
| Yes | |
| No | |
| No | |
| No | |
| No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
| GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
|---|---|---|---|---|
| 33715 | Ceramic-on-polyethylene total hip prosthesis |
A sterile implantable artificial substitute for a diseased (e.g., arthritic) or injured hip joint consisting of matching femoral (head/shaft) and acetabular components articulated at a ceramic-on-polyethylene or cross-linked polyethylene (PE) interface. Fixation devices for implantation (e.g., screws and bolts) may be included and implantation may be performed with or without bone cement.
|
Active | true |
| 34204 | Ceramic-on-ceramic total hip prosthesis |
A sterile implantable artificial substitute for a diseased (e.g., arthritic) or injured hip joint consisting of matching femoral (head/shaft) and acetabular components articulated at a ceramic-on-ceramic interface. Fixation devices for implantation (e.g., screws and bolts) may be included and implantation may be performed with or without bone cement.
|
Active | true |
FDA Product Code
[?]| Product Code | Product Code Name |
|---|---|
| LZO | Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented |
| MEH | Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate |
| KWY | Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented |
| LWJ | Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented |
FDA Premarket Submission
| FDA Premarket Submission Number [?] | Supplement Number [?] |
|---|---|
| K122185 | 000 |
Sterilization
Storage and Handling
[?]| Storage and Handling |
|---|
| No storage/handling found |
Clinically Relevant Size
[?]| Size Type Text |
|---|
| Angle: 0 degree |
| Lumen/Inner Diameter: 28 Millimeter |
| Outer Diameter: 44 Millimeter |
Device Record Status
84519af8-abd9-4c10-8162-6436e5cf021f
August 07, 2018
4
October 24, 2015
August 07, 2018
4
October 24, 2015
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]| Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
|---|---|---|---|---|---|
| No Package DIs found | |||||
Secondary DI
[?]| Issuing Agency [?] | Secondary DI Number |
|---|---|
| No Secondary DIs found | |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+886229294567
service@uoc.com.tw
service@uoc.com.tw