DEVICE: NA (04713616093651)
Device Identifier (DI) Information
NA
S1001-6060
In Commercial Distribution
CARILEX MEDICAL, INC.
S1001-6060
In Commercial Distribution
CARILEX MEDICAL, INC.
Canister for VT•100 - 300ml lock
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
47404 | Negative-pressure wound therapy system canister |
A receptacle for the collection of excess interstitial fluid, exudate, and infectious materials from a dedicated dressing that has been applied for a vacuum-assisted wound closure procedure; commonly known as negative pressure wound therapy (NPWT). It is typically made of transparent disposable plastic materials and is connected to or placed into the NPWT system's vacuum pump. This receptacle is a single-use device that should be discarded, including its contaminated waste content, according to the environmental legislation by which the user is bound (e.g., incineration, recycling, landfill).
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
KDQ | Bottle, Collection, Vacuum |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
c86cef66-8463-4196-ae79-0909fe3b13ad
May 03, 2024
7
March 22, 2017
May 03, 2024
7
March 22, 2017
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
04713616090308 | 5 | 04713616093651 | 2022-12-15 | Not in Commercial Distribution | |
04719873693825 | 12 | 04713616090308 | 2022-12-15 | Not in Commercial Distribution | |
14713616093658 | 5 | 04713616093651 | In Commercial Distribution | ||
24713616093655 | 12 | 14713616093658 | In Commercial Distribution |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
No Customer Contact currently defined