DEVICE: Cross-Seal (04719872920359)
Device Identifier (DI) Information
Cross-Seal
002
In Commercial Distribution
002
MEDEON BIODESIGN, INC.
002
In Commercial Distribution
002
MEDEON BIODESIGN, INC.
The Cross-Seal Device is composed of a Catheter, Suture Delivery System, and Handle.
The Cross-Seal Device tracks over a standard 0.038” or 0.035” (minimum length 130 cm) guidewire. A hemostasis valve located in the middle of the CATHETER limits blood flow from the GUIDEWIRE PORT through the CATHETER with or without the guidewire in place. The SUTURE DELIVERY SYSTEM contains NEEDLES, LOCATOR WINGS, and the NEEDLE BARREL that control suture placement around the arteriotomy. The HANDLE contains the SLIDER, BLEEDING INDICATOR, PLUNGER, RESET 1 BUTTON (SLIDER RETRACTOR), and RESET 2 BUTTON (LOCATOR WINGS RETRACTOR). The SLIDER triggers a mechanism that opens the LOCATOR WINGS and creates a sandwich configuration to stabilize the delivery system within the vessel wall. The BLEEDING INDICATOR connects to a lumen that has an intraluminal port positioned at the distal end of the Suture Delivery System to allow bleeding back to ensure Suture Delivery System is positioned properly in the femoral artery. The NEEDLE BARREL keeps the Cross-Seal Device from moving deeper inside the vessel, stabilizes the device once the LOCATOR WINGS are opened and retrieves the disengaged suture-carried NEEDLES. The PLUNGER triggers the NEEDLES to deploy sutures and simultaneously close the LOCATOR WINGS. The GUIDEWIRE GUIDE is the feature at distal handle portion which allows physician to practice coaxial insertion of device along guidewire if necessary.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
Yes | |
Yes | |
Yes | |
No | |
Yes | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
13909 | Polyolefin/fluoropolymer suture, monofilament |
A single-strand (monofilament), synthetic, non-bioabsorbable thread made of a polyolefin (e.g., polypropylene, polyethylene) or fluoropolymer (e.g., polytetrafluoroethylene, polyvinylidene fluoride) intended to join (i.e., approximate) the edges of a soft-tissue wound or incision by stitching or to ligate soft tissues; it may include an attached disposable device(s) [e.g., needle, passer] intended to facilitate suture application. The thread provides temporary wound support until the wound sufficiently heals to withstand normal stress. It is not a barbed suture and does not include antimicrobial agents/materials. This is a single-use device.
|
Active | true |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
MGB | Device, Hemostasis, Vascular |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
21c59bfa-8df4-4d25-b6e9-2e5b30492849
June 02, 2023
2
February 01, 2022
June 02, 2023
2
February 01, 2022
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
04719872920366 | 1 | 04719872920359 | In Commercial Distribution | Box | |
04719872920373 | 12 | 04719872920366 | In Commercial Distribution | Carton |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
No Customer Contact currently defined