DEVICE: Rocket (05055270966353)
Device Identifier (DI) Information
Rocket
R51549-12-PK
In Commercial Distribution
R51549-12-PK
ROCKET MEDICAL PLC
R51549-12-PK
In Commercial Distribution
R51549-12-PK
ROCKET MEDICAL PLC
Rocket 12Fg Seldinger Chest Drainage Kit
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
Yes | |
Yes | |
No | |
No | |
Yes | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
47200 | Pneumothorax catheter insertion set |
A collection of devices used to puncture the chest wall to enable insertion of a dedicated catheter for the aspiration of a simple pneumothorax or decompression of a tension pneumothorax. It typically consists of a scalpel to make a stab incision and a needle to assist the entry of the catheter with obturator assembly (to protect the internal organs upon entry). Once the catheter is in place, the needle is retracted to allow the flow of air/fluid from within the chest cavity. The set may contain suture for the attachment of the catheter to the skin. It is typically used for accident and emergency (A&E) situations (immediate care or chest crush injury). This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
No Product Codes |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Temperature: between -5 and 30 Degrees Celsius |
Handling Environment Humidity: between 1 and 70 Percent (%) Relative Humidity |
Handling Environment Atmospheric Pressure: exactly 101 KiloPascal |
Storage Environment Humidity: between 1 and 70 Percent (%) Relative Humidity |
Handling Environment Temperature: between -5 and 40 Degrees Celsius |
Storage Environment Atmospheric Pressure: exactly 101 KiloPascal |
Clinically Relevant Size
[?]Size Type Text |
---|
Catheter Gauge: 28.0 French |
Length: 40.0 Centimeter |
Device Record Status
d8433822-0323-47ab-8bc2-c7858158eb00
March 29, 2018
2
September 19, 2016
March 29, 2018
2
September 19, 2016
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
05055270966377 | 5 | 05055270966353 | In Commercial Distribution |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+4401914196988
gudid@rocketmedical.com
gudid@rocketmedical.com