DEVICE: ZENSOR (05060484630082)

Device Identifier (DI) Information

ZENSOR
PN1287
In Commercial Distribution

INTELESENS LIMITED
05060484630082
GS1

1
231959888 *Terms of Use
The zensor monitoring device is a small, lightweight, wearable, non-invasive, re-chargeable battery operated portable system connected to an electrode accessory (single-use disposable Intelesens zensor Electrode Array) which in turn is in contact with the patient’s body. The device is to be used in the patient’s home environment to provide clinicians with patient physiological data, while allowing for patient mobility. The zensor monitoring system provides full disclosure ECG and cardiac event monitoring for adult patients. The physiological parameters monitored include ECG and Respiration waveforms, Heart Rate and Respiration Rate, as well as lethal and high acuity arrhythmias (Asystole, Tachycardia, Ventricular Fibrillation, Bradycardia and Atrial Fibrillation). The zensor monitoring device has the option to store full disclosure ECG & Respiration data and/or wirelessly transmit pre-defined event alerts to the Intelesens zensoronline system for review by healthcare practitioners. All physiological data stored on the device can be downloaded for viewing on Intelesens zensor+ (Ambulatory ECG Full Disclosure ECG and Event Viewer) for later analysis by a clinician.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
31733 Electrocardiography telemetric monitoring system
An assembly of devices designed to continuously measure and wirelessly transmit electrocardiographic (ECG) signals from a patient to a receiving location (e.g., central station, bedside monitor) for viewing. It typically consists of a portable transmitter with antenna and attached sensors (e.g., leads and electrodes) that are connected to the patient, as well as a receiver typically incorporated into a central station or bedside monitor that receives, consolidates, and displays the information. The system is typically used for ambulatory patients who require continuous monitoring (e.g., patients in step-down care areas).
Obsolete false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
MHX Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K151027 000
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

08560d5b-b5c1-4e89-8763-2ccf0f21dbf1
February 07, 2019
1
January 07, 2019
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
15060484630089 1 05060484630082 In Commercial Distribution
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
Yes
No CLOSE

Customer Contact

[?]
No Customer Contact currently defined
CLOSE