DEVICE: Pure-Vu (05060513700007)

Device Identifier (DI) Information

Pure-Vu
PV-WS-001
In Commercial Distribution
PV-WS-001
MOTUS GI MEDICAL TECHNOLOGIES LTD
05060513700007
GS1

1
532775983 *Terms of Use
(1) Workstation with foot pedal
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
12301 Colonic lavage system, powered-flow
A device assembly designed for automated or semi-automated irrigation, washing, and evacuation of debris from the colon. It typically consists of a mains electricity (AC-powered) electromechanical unit that includes a pump for infusion of non-medicated fluids (e.g., saline), an extractor (frequently using vacuum), and controls for the temperature and the rate of infusion (e.g., using a nozzle) and withdrawal of the liquid; the system is coupled to dedicated handpieces and/or to disposable catheters introduced through the rectum. It is intended to be used by a healthcare provider in a clinical setting to remove damaged tissue and/or debris (e.g., faeces, foreign objects).
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
FDF Colonoscope And Accessories, Flexible/Rigid
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K160015 000
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Handling Environment Atmospheric Pressure: between 0 and 81 KiloPascal
Handling Environment Humidity: between 10 and 80 Percent (%) Relative Humidity
Handling Environment Temperature: between 10 and 30 Degrees Celsius
Storage Environment Humidity: between 10 and 80 Percent (%) Relative Humidity
Storage Environment Temperature: between -10 and 60 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

582c165a-626d-4079-bca0-ec36619448ea
July 06, 2018
3
January 03, 2017
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
No
No CLOSE

Customer Contact

[?]
888-438-9996
customer@motusgi.com
CLOSE