DEVICE: SJM™ Masters Series HP Gelweave Valsalva (05414734009508)

Device Identifier (DI) Information

SJM™ Masters Series HP Gelweave Valsalva
29VAVGJ-515
In Commercial Distribution
29VAVGJ-515
ST. JUDE MEDICAL, INC.
05414734009508
GS1

1
149818952 *Terms of Use
St. Jude Medical Valved Graft HP Rotatable Mechanical Heart Valve
CLOSE

Device Characteristics

MR Conditional
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
60423 Aortic bi-leaflet mechanical heart valve prosthesis/biologic-polymer aorta graft
An artificial substitute for a natural aortic heart valve fitted with a length of biologic-polymer blood vessel (vascular graft) intended to be implanted during open heart surgery to simultaneously replace a dysfunctional aortic heart valve and repair/replace a damaged or diseased ascending aorta (e.g., in cases of aneurysm, dissection or dilatation). The valve component consists of two flat, semicircular, pyrolytic carbon-coated or polymer leaflets that pivot about struts attached to the valve housing by hinges; the synthetic polymer blood vessel is designed to conform to the aortic root anatomy and is impregnated with a bioabsorbable animal-derived gelatin.
Active true
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
LWQ HEART-VALVE, MECHANICAL
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Special Storage Condition, Specify: Store in a cool, dry area.
Handling Environment Temperature: between 0 and 35 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Outer Diameter: 29 Millimeter
CLOSE

Device Record Status

e1163b99-feb2-4577-9099-1d797c754e98
February 05, 2021
4
September 23, 2014
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
Yes
No
No CLOSE

Customer Contact

[?]
+1(855)478-5833
customerservice@sjm.com
CLOSE