DEVICE: Assurity MRI™ (05414734509589)

Device Identifier (DI) Information

Assurity MRI™
PM2272
In Commercial Distribution
PM2272
ST. JUDE MEDICAL, INC.
05414734509589
GS1

1
790268031 *Terms of Use
DR Pacemaker DDDR
CLOSE

Device Characteristics

MR Conditional
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
47265 Dual-chamber implantable pacemaker, rate-responsive
A battery-powered, hermetically-sealed pulse generator, implanted beneath the skin of the chest in a surgically-created pocket, with pacing leads in or on two chambers of the heart (right atrium and ventricle). It is intended to stimulate the chambers of an abnormal heart, through electrical impulses, to beat in their natural sequence, and to adjust the rate of contraction to meet the body's increased need for blood flow due to activity. It contains one or more sensors to detect changes in the body (e.g., motion, breathing frequency) to indicate more oxygen is needed, and subsequently increases the pacing rate; it is not intended for defibrillation therapy.
Active true
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
LWP Implantable pulse generator, pacemaker (non-CRT)
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
P140033 000
P140033 008
P140033 017
P140033 041
P140033 049
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Temperature: between 15 and 30 Degrees Celsius
Special Storage Condition, Specify: Keep dry. Keep away from sunlight. Protect from heat and radioactive sources.
Handling Environment Temperature: between -4 and 140 Degrees Fahrenheit
Storage Environment Temperature: between 59 and 86 Degrees Fahrenheit
Handling Environment Temperature: between -20 and 60 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

1cae5f49-9d73-4288-9fa3-27ca5ac6c7d3
October 02, 2024
8
February 07, 2017
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
Yes
No
No CLOSE

Customer Contact

[?]
+1(855)478-5833
customerservice@sjm.com