DEVICE: A127™ (05415067018441)
Device Identifier (DI) Information
Device Characteristics
| Labeling does not contain MRI Safety Information | |
| No | |
| No | |
| Yes | |
| Yes | |
| No | |
| No | |
| No | |
| No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
| GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
|---|---|---|---|---|
| 65308 | Spinal cord/peripheral nerve implantable analgesic electrical stimulation system lead extension |
An implantable device intended to extend the electrical connection between a spinal cord/peripheral nerve implantable analgesic electrical stimulation system pulse generator and a lead(s). It typically includes small connectors to enable attachment to the lead(s) and pulse generator, and a length of insulated wire; the lead(s) and pulse generator are not included.
|
Active | true |
FDA Product Code
[?]| Product Code | Product Code Name |
|---|---|
| LGW | STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF |
FDA Premarket Submission
| FDA Premarket Submission Number [?] | Supplement Number [?] |
|---|---|
| P010032 | 008 |
Sterilization
Storage and Handling
[?]| Storage and Handling |
|---|
| Handling Environment Atmospheric Pressure: between 70 and 150 KiloPascal |
| Storage Environment Humidity: between 10 and 90 Percent (%) Relative Humidity |
| Storage Environment Atmospheric Pressure: between 70 and 150 KiloPascal |
| Storage Environment Temperature: between -10 and 55 Degrees Celsius |
| Handling Environment Temperature: between -10 and 55 Degrees Celsius |
| Handling Environment Humidity: between 10 and 90 Percent (%) Relative Humidity |
Clinically Relevant Size
[?]| Size Type Text |
|---|
| Length: 60 Centimeter |
Device Record Status
2697f55b-870f-4585-8482-77ad100144b3
July 02, 2025
5
March 23, 2015
July 02, 2025
5
March 23, 2015
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]| Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
|---|---|---|---|---|---|
| No Package DIs found | |||||
Secondary DI
[?]| Issuing Agency [?] | Secondary DI Number |
|---|---|
| No Secondary DIs found | |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(855)478-5833
customerservice@sjm.com
customerservice@sjm.com