DEVICE: ABL90 FLEX PLUS Analyzer (05700693930923)
Device Identifier (DI) Information
ABL90 FLEX PLUS Analyzer
393-092
In Commercial Distribution
393-092
Radiometer Medical ApS
393-092
In Commercial Distribution
393-092
Radiometer Medical ApS
ABL90 FLEX PLUS, Analyzer without casettes, cables, manuals etc.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
56667 | Metabolic profile clinical chemistry analyser IVD |
A portable, electrically-powered automated or semi-automated laboratory instrument intended to be used for the qualitative and/or quantitative in vitro measurement of multiple clinical chemistry analytes to generate a metabolic profile. Analytes may include pH, blood gas parameters (e.g., pO2, pCO2), electrolytes [e.g., Sodium (Na2+), potassium (K+), chloride (Cl-)], glucose, urea, creatinine and sometimes in addition haemoximetry parameters [e.g., carboxy-haemoglobin (COHb), methaemoglobin (MetHb), total haemoglobin (totHb), hematrocrit (Hct)].
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
MQM | BILIRUBIN (TOTAL AND UNBOUND) IN THE NEONATE TEST SYSTEM |
KQI | ASSAY, FETAL HEMOGLOBIN |
KHP | ACID, LACTIC, ENZYMATIC METHOD |
JFP | ELECTRODE, ION SPECIFIC, CALCIUM |
CEM | ELECTRODE, ION SPECIFIC, POTASSIUM |
JGS | ELECTRODE, ION SPECIFIC, SODIUM |
CHL | ELECTRODE MEASUREMENT, BLOOD-GASES (PCO2, PO2) AND BLOOD PH |
JIX | CALIBRATOR, MULTI-ANALYTE MIXTURE |
CGA | GLUCOSE OXIDASE, GLUCOSE |
GKR | SYSTEM, HEMOGLOBIN, AUTOMATED |
JJY | Multi-analyte controls, all kinds (assayed) |
CGZ | ELECTRODE, ION-SPECIFIC, CHLORIDE |
GHS | ASSAY, CARBOXYHEMOGLOBIN |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Temperature: between -20 and 60 Degrees Celsius |
Handling Environment Temperature: between 15 and 32 Degrees Celsius |
Handling Environment Atmospheric Pressure: between 70 and 107 KiloPascal |
Handling Environment Humidity: between 10 and 80 Percent (%) Relative Humidity |
Special Storage Condition, Specify: Labeling does not contain MRI Safety information |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
788523a7-263f-413c-8900-4ad2e6a84dd8
November 14, 2024
5
February 15, 2017
November 14, 2024
5
February 15, 2017
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+45999999999
radiometer@radiometer.dk
radiometer@radiometer.dk