DEVICE: ABL80 FLEX Analyzer (05700693938394)

Device Identifier (DI) Information

ABL80 FLEX Analyzer
393-839
Not in Commercial Distribution
393-839
Radiometer Medical ApS
05700693938394
GS1
July 14, 2023
1
308667539 *Terms of Use
ABL80 FLEX Full panel, Analyzer
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
56667 Metabolic profile clinical chemistry analyser IVD
A portable, electrically-powered automated or semi-automated laboratory instrument intended to be used for the qualitative and/or quantitative in vitro measurement of multiple clinical chemistry analytes to generate a metabolic profile. Analytes may include pH, blood gas parameters (e.g., pO2, pCO2), electrolytes [e.g., Sodium (Na2+), potassium (K+), chloride (Cl-)], glucose, urea, creatinine and sometimes in addition haemoximetry parameters [e.g., carboxy-haemoglobin (COHb), methaemoglobin (MetHb), total haemoglobin (totHb), hematrocrit (Hct)].
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
CHL ELECTRODE MEASUREMENT, BLOOD-GASES (PCO2, PO2) AND BLOOD PH
GKR SYSTEM, HEMOGLOBIN, AUTOMATED
GHS ASSAY, CARBOXYHEMOGLOBIN
CGZ ELECTRODE, ION-SPECIFIC, CHLORIDE
DQA Oximeter
CEM ELECTRODE, ION SPECIFIC, POTASSIUM
CGA GLUCOSE OXIDASE, GLUCOSE
JJY Multi-analyte controls, all kinds (assayed)
JPI DEVICE, HEMATOCRIT MEASURING
JGS ELECTRODE, ION SPECIFIC, SODIUM
JFP ELECTRODE, ION SPECIFIC, CALCIUM
JIX CALIBRATOR, MULTI-ANALYTE MIXTURE
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Special Storage Condition, Specify: Fragile
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

9864d2f6-eda4-415e-8462-8b05d404db00
August 01, 2023
5
September 01, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
No
No CLOSE

Customer Contact

[?]
+459999999999
radiometer@radiometer.dk
CLOSE