DEVICE: Cardiospy ECG Holter System (05999883490006)

Device Identifier (DI) Information

Cardiospy ECG Holter System
EC-2H
In Commercial Distribution

LABTECH Kereskedelmi és Mérnöki Szolgáltató Korlátolt Felelősségű Társaság
05999883490006
GS1

1
520963286 *Terms of Use
The battery powered Cardiospy ECG Holter System provides 1, 2 channel recordings, depending on the recorder and patient cable type being used. The Cardiospy ECG Holter System includes a recorder, an USB dongle (for bluetooth communication) and the Cardiospy software. The Class II medical device is intended to acquire, record and store up to 24, 48, 72 hours and 1 week of ECG data of patients that have been connected to the recorder and are undergoing Holter monitoring and to support the medical staff in analyzing and deciding the proper and adequate diagnosis. The cardiac data and analysis provided by Cardiospy ECG Holter System will be reviewed, confirmed, and used by trained medical personnel in the diagnosis of patients with various rhythm patterns. The universal analysis SW provides full disclosure ECG recordings on channels with a precise automatic QRS and PM detection, template and rhythm analysis, QRS classification, efficient ST, QT, AF, PM, HRV time and frequency based analysis with color coded display and printing with interactive modification possibilities in the automatic analysis in several languages. Export-import and archiving option of the recordings is available. The evaluation software works with a conventional PC- based computer under Win 2000/XP/VISTA , Windows 7, Windows 8, Windows 10 operating systems. The connection between the Holter and computer is performed by using Bluetooth and USB dongle. The Cardiospy analysis software provides ECG records of excellent quality.
CLOSE

Device Characteristics

MR Unsafe
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
36827 Electrocardiographic long-term ambulatory recording analyser
An electronic device intended to be used for the analysis of long-term (often 24-hours) heart activity data, which has previously been registered by an electrocardiographic long-term ambulatory recorder (Holter), to which the patient was connected and carried upon his or her person.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
MLO Electrocardiograph, Ambulatory, With Analysis Algorithm
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K140847 000
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Length: 67.5 Millimeter
Width: 53 Millimeter
Width: 18.5 Millimeter
Weight: 50 Gram
CLOSE

Device Record Status

a3a94da4-ed91-4593-bf03-d0928b75d1e7
July 06, 2018
3
December 06, 2017
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
Yes
No CLOSE

Customer Contact

[?]
No Customer Contact currently defined
CLOSE