DEVICE: Brilliant (06936733738245)

Notice: Any discrepancies with this record compared to the label?
If so, send a picture of the label to GUDIDSupport@fda.hhs.gov.

Device Identifier (DI) Information

Brilliant
ACS061635
In Commercial Distribution

Lepu Medical Technology (Beijing) Co.,Ltd.
06936733738245
GS1

1
529853921 *Terms of Use
The puncture needle or an intravascular catheter incorporates a lumen, which provides a conduit for the insertion of the guide wire into the vascular system. The various types of guide wires, model dependent, are utilized as a guiding mechanism for the insertion of the introduction sheath into the vascular system. The guide wire contains a wire collimator, which assists in funneling the wire through the lumen of the puncture needle or the intravascular catheter and contains marking that are visible under fluoroscopy, which can determine the length of the guide wire within the vascular system. The sheath introducer provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vasculature. The main components of the sheath introducer assembly are a hydrophilic coated sheath introducer, hemostasis valve housing, and a side port with tubing connected to a 3-way stopcock/valve. The hydrophilic coated dilator is used to provide support and stability to the sheath introducer during deployment into the vascular system. The proximal end of the dilator includes a luer port and has a tapered, atraumatic distal tip. Both the sheath and dilator contain bismuth, making these devices visible under fluoroscopy.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
Yes
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
58865 Vascular catheter introduction set, nonimplantable
A collection of nonimplantable, invasive devices intended to provide percutaneous vascular access to enable introduction of a catheter (not included) into the vascular system. It includes a non-steerable introducer sheath with an inner obturator/dilator, and typically an additional access device(s) [e.g., guidewire, introducer needle, syringe, additional dilators] which may include a haemostatic valve to control blood loss, usually to enable arterial access. This is a single-use device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
DYB Introducer, Catheter
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

1b4583b7-43cd-4ebd-aef0-acb7fb59c222
April 24, 2026
1
April 16, 2026
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
16936733738242 5 06936733738245 In Commercial Distribution Box
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
No Customer Contact currently defined
CLOSE