DEVICE: SeQureTM Snare System (06938370118015)

Device Identifier (DI) Information

SeQureTM Snare System
LT-SG-05
In Commercial Distribution

Lifetech Scientific (Shenzhen) Co., Ltd.
06938370118015
GS1

1
529864170 *Terms of Use
The SeQureTM Snare System consists of a snare, a catheter, a loader and a torquer. The snare is constructed of a nitinol shaft and a loop with the plane of the loop perpendicular to the nitinol shaft. The nitinol loop is covered with a tungsten coil which is coated by laminated titanium and its nitride to enhance radiopaque. The pre-formed snare loop can be introduced through catheter without risk of permanent deformiation because of super-elasticity of nitinol material. The catheter consists of luer connector and PE tubing with a radiopaque markband at its distal tip to enhance the visibility during the operation. The snare is pre-assembled with the loader and the torque, and then packaged together with corresponding catheter.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
17927 Intravascular extraction catheter-snare
A flexible, end- and/or side-hole tube with a long snaring device (e.g., a wire loop or noose) inserted through its lumen, designed to be introduced into a blood vessel or similar structure to manually retrieve or manipulate a foreign body. It is typically available in two forms: 1) the loop emerges from the distal tip of the catheter while both free ends of the wire emerge from the proximal end; and 2) the end of the wire is attached to the distal end of the catheter while the free end is passed through the lumen to emerge at the proximal end. The wire is usually made of a high-strength, stiff metal [e.g., nickel-titanium alloy (Nitinol)].
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
MMX Device, Percutaneous Retrieval
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K102484 000
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

4d6727ac-74f2-4ec9-8f74-bcb4623478c6
July 08, 2021
4
November 17, 2017
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
Yes
Yes
Yes
No CLOSE

Customer Contact

[?]
No Customer Contact currently defined
CLOSE