DEVICE: Synxess (06945258302022)
Device Identifier (DI) Information
Synxess
GW1410
In Commercial Distribution
Enlight Medical Technologies(Shenzhen) Co., Ltd.
GW1410
In Commercial Distribution
Enlight Medical Technologies(Shenzhen) Co., Ltd.
This product is comprised of a stainless steel core wire with distal platinum tungsten coil and proximal stainless steel coil, and includes a shaping mandrel and a torque device. The guidewire distal tip is straight and shapeable. The diameters of the guidewires are listed in the table below. The guidewires are compatible with devices with inner diameters (IDs) specified in the table below. The distal 30 mm of the guidewire tip is radiopaque. Confirm the compatibility of the guidewire diameter with the interventional device before use.
For lubricity, the distal 300 mm of the device is coated with hydrophilic coating and the proximal portion of the guidewire is coated with hydrophobic polytetrafluoroethylene (PTFE).The shaping mandrel included with the guidewire can be used to shape the tip of the guidewire as appropriate. When shaping the tip, carefully crimp it while the surface is wet. The torque device included with the guidewire attaches to the proximal end of the wire and functions as a steering guide. Rotation of the torque device facilitates guidewire placement into the target vessel by manipulation of the guidewire tip.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
60940 | Neurovascular embolization coil |
A non-bioabsorbable, implantable device intended to induce a neurovascular thrombosis to treat an intracranial aneurysm and/or neurovascular arteriovenous malformation (AVM); it may also be intended to treat non-neurovascular malformations. It is in the form of a metal [e.g., platinum alloy] or metal/synthetic polymer wire which coils upon deployment within the aneurysm/vasculature; it is typically pre-attached to a nonimplantable delivery wire. Disposable devices associated with implantation (e.g., delivery wire, catheter) may be included.
|
Active | true |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
MOF | Guide, Wire, Catheter, Neurovasculature |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K240871 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
24c38b7c-e6f3-407d-855b-960dac5c2f33
February 17, 2025
1
February 08, 2025
February 17, 2025
1
February 08, 2025
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
No Customer Contact currently defined