DEVICE: Cryoprobe (07290015487542)

Device Identifier (DI) Information

Cryoprobe
CP-2004059
In Commercial Distribution

ICECURE MEDICAL LTD
07290015487542
GS1

1
514758619 *Terms of Use
90-degree handle
CLOSE

Device Characteristics

MR Unsafe
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
60508 Hand-held cryosurgical system handpiece tip
A sterile component of a hand-held cryosurgery system intended to be attached to the system handpiece to deliver liquid refrigerant (cryogen) [e.g., liquid nitrogen (LN2), nitrous oxide (N2O), carbon dioxide (CO2)] to skin/subcutaneous tissues for cryotherapy applications (e.g., surgical ablation, cosmetic, analgesic). It is typically a closed-end needle intended to deliver focused cooling to the therapy site without destroying healthy tissues. This is a single-use device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
GEH Unit, Cryosurgical, Accessories
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K240892 000
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Handling Environment Temperature: between -22 and 60 Degrees Celsius
Handling Environment Humidity: between 25 and 75 Percent (%) Relative Humidity
Handling Environment Atmospheric Pressure: between 500 and 1000 millibar
Storage Environment Temperature: between 15 and 25 Degrees Celsius
Storage Environment Humidity: between 0 and 60 Percent (%) Relative Humidity
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Needle Gauge: 10 Gauge
Shaft Length: 140 Millimeter
CLOSE

Device Record Status

020842d7-db20-47a7-9be1-6d79e53f7104
May 14, 2025
1
May 06, 2025
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
17290015487549 5 07290015487542 In Commercial Distribution Box
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
Yes
No CLOSE

Customer Contact

[?]
18889025716
icecuresupport@icecure-medical.com
CLOSE