DEVICE: POLLOGEN LEGEND (07290016586039)

Device Identifier (DI) Information

POLLOGEN LEGEND
POLLOGEN LEGEND+
In Commercial Distribution
21400370
POLLOGEN LTD
07290016586039
GS1

1
514905681 *Terms of Use
Applicators 1-3 provide RF energy that heats biological tissue in a controlled fashion for non-ablative therapeutic effects. Non ablative effects are used to trigger collagen remodeling for the treatment of wrinkles and rhytides. Applicator No.3 is indicated for the treatment of very small facial areas. It is connected to the main unit by a cable containing electrical wiring and a connector, also consisting of a plastic body with integrated electronic system, 3 electrodes and indication light guide ring.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
58454 Radio-frequency skin surface treatment system
An assembly of devices designed to apply radio-frequency (RF) energy to heat the skin surface for ablation, coagulation, and tightening of the skin’s outer later (stratum corneum) for aesthetic skin resurfacing. It primarily consists of a mains electricity (AC-powered) control unit to produce and regulate the RF energy, and a connected bipolar RF applicator (handpiece) to deliver the RF energy to the skin surface; the applicator may include vacuum to facilitate its coupling with the skin.
Obsolete false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
GEI Electrosurgical, Cutting & Coagulation & Accessories
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K111026 000
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

d994ec83-0d15-453a-89e0-d1bb5bcf7e9c
July 06, 2018
3
April 06, 2017
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
Yes
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
No
No CLOSE

Customer Contact

[?]
No Customer Contact currently defined
CLOSE