DEVICE: VRPhysio (07290016986099)
Device Identifier (DI) Information
VRPhysio
N-140 (Rotate)
In Commercial Distribution
XR HEALTH IL LTD
N-140 (Rotate)
In Commercial Distribution
XR HEALTH IL LTD
A software-only medical device intended for cervical region rehabilitation. The software tracks motion and movement kinematics and guides patients in the performance of physical exercises according to their treating medical practitioner's guidelines. The N-140 is a prescription-only device that can be used in clinical setting or at home, with or without the assistance of clinician. N-140 does not provide a report that analyzes the measurements, makes medical diagnoses, or recommends treatment.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
63312 | Biomechanical function analysis/interactive rehabilitation system |
A computerized device assembly designed for: 1) analysis of biomechanical/neuromuscular function using dedicated hardware; and 2) neuromuscular rehabilitation therapy at multiple anatomical sites based on patient interaction with dedicated physical-response measuring hardware (e.g., dynamometer, standing force plates, EMG electrodes) providing feedback in a videogame-like format. It includes multiple pieces of neuromuscular function analysis and physical-response measuring hardware, computer interface devices and dedicated software; it is intended to be used with an off-the-shelf computer. It is not based on tracking movement through space (i.e., not a virtual-display rehabilitation system).
|
Active | false |
47518 | Biomechanical function analysis/rehabilitation software |
A software package intended to be used by patients and clinicians to receive and display a patient’s physical exercise/movement/action data [e.g., kinesiology/gait data (walking speed or distance)] to facilitate analysis as part of physical assessment/rehabilitation. It is intended to be used while using an interactive rehabilitation system, biomechanical function analysis system and/or kinesiology recorder (ambulatory or implantable). It might be intended to function in conjunction with a motion-sensing system/device or limb-support robotic system, and may be capable of storing and/or enable viewing of patient performance data.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
ISD | Exerciser, Measuring |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
4808d6ad-e039-411f-8203-52ee1175e841
February 05, 2024
5
October 16, 2019
February 05, 2024
5
October 16, 2019
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1 (857)-990-6111
support@xr.health
support@xr.health