DEVICE: Nonagon (07290018446102)
Device Identifier (DI) Information
Nonagon
N9
In Commercial Distribution
MHD-100-02-001
NONAGON LTD
N9
In Commercial Distribution
MHD-100-02-001
NONAGON LTD
The Nonagon N9 device is a home use device. The device is comprised of a handheld unit that connects with a smartphone and a dedicated smartphone software application that runs on the user's personal smartphone An API is defined to enable healthcare providers to communicate with the device.
The Device enables user’s examination at home with or without the guidance of a remote physician. It also enables guidance and data examination by a remote physician over an IP network. The Smartphone Application controls the Handheld Unit's functionality and processes and displays the collected data. The N9 device measure, record, and transmit data of auscultation sound of human body (lung, hear, abdomen), temperature, oxygen saturation (SpO2) and pulse rate, and can be used to send images of an examined body part. In addition, the device includes otoscope where images of the ear can be transmitted to the healthcare provider.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
45607 | Pulse oximeter |
An electrically-powered photoelectric device designed for the transcutaneous measurement and display of haemoglobin oxygen saturation (SpO2). The signals are produced by light-emitting diodes (LEDs) and received by a photodetector. The device displays the SpO2 values and may also measure/display pulse rate. It is typically applied to the fingertip or around the wrist, may be single-component (with built-in probe) or multi-component (includes external probe), and may in addition wirelessly transmit measurements to a receiving location (e.g., central station, bedside monitor); it is intended to be operated by laypersons and healthcare providers.
|
Active | false |
13754 | Electronic acoustic stethoscope |
An external, hand-held, electronic listening device designed to be used by a healthcare professional for real-time detection and amplification of body sounds (e.g., heart, blood vessels, lungs) that may be difficult to perceive when using a mechanical stethoscope; it is not designed for electrocardiography (ECG). It is typically designed to be connected to a computing device, which may operate interpretive software sometimes provided with the stethoscope, for recording and/or displaying the results in the form of a graph [phonocardiogram (PCG)].
|
Active | false |
12849 | Otoscope, direct |
An electrically-powered, hand-held device designed for examination of the outer ear canal and tympanic membrane (eardrum) by direct viewing through the ear opening. It consists of a main unit (commonly referred to as the head) with a built-in light source intended to illuminate the interior of the ear canal with a detachable cone-shaped tube (speculum) inserted in the ear canal; it may facilitate the application of air pressure for pneumatic otoscopy. A dedicated power supply handpiece and/or an insufflation bulb may be included with the head.
|
Active | false |
17888 | Infrared patient thermometer, skin |
A hand-held, electrically-powered instrument designed to estimate the temperature of a site on the skin (e.g., axilla, forehead) by measurement of body infrared emissions at this particular point. It provides a method to determine temperature patterns or variations on the surface of the skin (e.g., due to differences in perfusion). This device may be used in the home. This is a reusable device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
DQA | Oximeter |
DQD | Stethoscope, Electronic |
ERA | Otoscope |
FLL | Thermometer, Electronic, Clinical |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K202483 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
c455faa5-308b-4a6b-8f58-2685a4c56fff
November 25, 2024
5
May 26, 2021
November 25, 2024
5
May 26, 2021
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
17290018446109 | 1 | 07290018446102 | In Commercial Distribution |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
No Customer Contact currently defined