DEVICE: Nonagon (07290018446102)

Device Identifier (DI) Information

Nonagon
N9
In Commercial Distribution
MHD-100-02-001
NONAGON LTD
07290018446102
GS1

1
532283903 *Terms of Use
The Nonagon N9 device is a home use device. The device is comprised of a handheld unit that connects with a smartphone and a dedicated smartphone software application that runs on the user's personal smartphone An API is defined to enable healthcare providers to communicate with the device. The Device enables user’s examination at home with or without the guidance of a remote physician. It also enables guidance and data examination by a remote physician over an IP network. The Smartphone Application controls the Handheld Unit's functionality and processes and displays the collected data. The N9 device measure, record, and transmit data of auscultation sound of human body (lung, hear, abdomen), temperature, oxygen saturation (SpO2) and pulse rate, and can be used to send images of an examined body part. In addition, the device includes otoscope where images of the ear can be transmitted to the healthcare provider.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
45607 Pulse oximeter
An electrically-powered photoelectric device designed for the transcutaneous measurement and display of haemoglobin oxygen saturation (SpO2). The signals are produced by light-emitting diodes (LEDs) and received by a photodetector. The device displays the SpO2 values and may also measure/display pulse rate. It is typically applied to the fingertip or around the wrist, may be single-component (with built-in probe) or multi-component (includes external probe), and may in addition wirelessly transmit measurements to a receiving location (e.g., central station, bedside monitor); it is intended to be operated by laypersons and healthcare providers.
Active false
13754 Electronic acoustic stethoscope
An external, hand-held, electronic listening device designed to be used by a healthcare professional for real-time detection and amplification of body sounds (e.g., heart, blood vessels, lungs) that may be difficult to perceive when using a mechanical stethoscope; it is not designed for electrocardiography (ECG). It is typically designed to be connected to a computing device, which may operate interpretive software sometimes provided with the stethoscope, for recording and/or displaying the results in the form of a graph [phonocardiogram (PCG)].
Active false
12849 Otoscope, direct
An electrically-powered, hand-held device designed for examination of the outer ear canal and tympanic membrane (eardrum) by direct viewing through the ear opening. It consists of a main unit (commonly referred to as the head) with a built-in light source intended to illuminate the interior of the ear canal with a detachable cone-shaped tube (speculum) inserted in the ear canal; it may facilitate the application of air pressure for pneumatic otoscopy. A dedicated power supply handpiece and/or an insufflation bulb may be included with the head.
Active false
17888 Infrared patient thermometer, skin
A hand-held, electrically-powered instrument designed to estimate the temperature of a site on the skin (e.g., axilla, forehead) by measurement of body infrared emissions at this particular point. It provides a method to determine temperature patterns or variations on the surface of the skin (e.g., due to differences in perfusion). This device may be used in the home. This is a reusable device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
DQA Oximeter
DQD Stethoscope, Electronic
ERA Otoscope
FLL Thermometer, Electronic, Clinical
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K202483 000
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

c455faa5-308b-4a6b-8f58-2685a4c56fff
November 25, 2024
5
May 26, 2021
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
17290018446109 1 07290018446102 In Commercial Distribution
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
Yes
No CLOSE

Customer Contact

[?]
No Customer Contact currently defined
CLOSE