DEVICE: InMode RF hand piece (07290019863052)
Device Identifier (DI) Information
InMode RF hand piece
HP253966A
Not in Commercial Distribution
HP253966A
INMODE M.D LTD
HP253966A
Not in Commercial Distribution
HP253966A
INMODE M.D LTD
Handpiece comprises internal active electrode, external return electrode, both with temperature sensor, handle, cable and connector.
Handpiece HP253966A has an active electrode diameter of 3.3mm and return electrode of 24mm diameter and 25cm long. Maximal RF power 60W.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
48005 | Radio-frequency fat liquefaction system |
An assembly of devices using radio-frequency (RF) energy for simultaneous adipose tissue liquefaction, blood vessel coagulation, and skin tightening during a radio-frequency-assisted liposuction (RFAL) procedure [lipectomy], typically performed for body contouring. The system consists of an RF-generating control unit that supplies RF energy to a dedicated applicator (handpiece) and provides continuous tissue temperature monitoring; impedance and power monitoring with tissue overheating safety systems; the RF applicator; and a foot-switch to control the RF energy supply. The liquified tissue is aspirated with an independent external suction system.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
GEI | Electrosurgical, Cutting & Coagulation & Accessories |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K233642 | 000 |
K240780 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Handling Environment Humidity: between 0 and 90 Percent (%) Relative Humidity |
Handling Environment Temperature: between 10 and 35 Degrees Celsius |
Storage Environment Humidity: between 0 and 90 Percent (%) Relative Humidity |
Storage Environment Temperature: between 10 and 35 Degrees Celsius |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
5e6784c3-b669-4c17-ba68-707118e74a5a
February 21, 2025
2
April 25, 2024
February 21, 2025
2
April 25, 2024
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
1-887-367-4556
contact@inmode.com
contact@inmode.com