DEVICE: InMode RF hand piece (07290019863298)

Device Identifier (DI) Information

InMode RF hand piece
HP172296A
In Commercial Distribution
HP172296A
INMODE M.D LTD
07290019863298
GS1

1
600417351 *Terms of Use
InModeRF HP 17x22x46 black
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
48005 Radio-frequency fat liquefaction system
An assembly of devices using radio-frequency (RF) energy for simultaneous adipose tissue liquefaction, blood vessel coagulation, and skin tightening during a radio-frequency-assisted liposuction (RFAL) procedure [lipectomy], typically performed for body contouring. The system consists of an RF-generating control unit that supplies RF energy to a dedicated applicator (handpiece) and provides continuous tissue temperature monitoring; impedance and power monitoring with tissue overheating safety systems; the RF applicator; and a foot-switch to control the RF energy supply. The liquified tissue is aspirated with an independent external suction system.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
GEI Electrosurgical, Cutting & Coagulation & Accessories
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K240780 000
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Handling Environment Humidity: between 10 and 90 Percent (%) Relative Humidity
Handling Environment Temperature: between 10 and 35 Degrees Celsius
Storage Environment Humidity: between 10 and 90 Percent (%) Relative Humidity
Storage Environment Temperature: between 10 and 35 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

f3b32b5a-fcf2-46c1-8c73-2a1502f63043
February 28, 2025
1
February 20, 2025
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
Yes
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
Yes
No CLOSE

Customer Contact

[?]
1-887-367-4556
contact@inmode.com
CLOSE