DEVICE: PCA Head (07613327012774)
Device Identifier (DI) Information
PCA Head
2284-0-428
In Commercial Distribution
2284-0-428
Howmedica Osteonics Corp.
2284-0-428
In Commercial Distribution
2284-0-428
Howmedica Osteonics Corp.
Femoral Head Component
Device Characteristics
| Labeling does not contain MRI Safety Information | |
| No | |
| No | |
| Yes | |
| Yes | |
| No | |
| No | |
| No | |
| No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
| GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
|---|---|---|---|---|
| 33175 | Metallic femoral head prosthesis |
An implantable artificial substitute for a diseased or injured femoral head that has an outer surface made of metal [e.g., cobalt-chrome (Co-Cr), titanium (Ti), stainless steel]. It is designed to be attached to the trunnion of a prosthetic femoral stem/shaft or a head/stem adaptor, and to articulate with an acetabulum prosthesis as part of a total hip arthroplasty (THA), or articulate with the natural acetabulum directly or via a bipolar component as part of a partial hip arthroplasty (hemiarthroplasty). The device ranges in form from partially to fully spherical (ball-shaped) and is available in various sizes.
|
Active | true |
FDA Product Code
[?]| Product Code | Product Code Name |
|---|---|
| LPH | PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED |
| KWL | Prosthesis, hip, hemi-, femoral, metal |
| MEH | Prosthesis, hip, semi-constrained, uncemented, metal/polymer, non-porous, calicum-phosphate |
| JDI | Prosthesis, hip, semi-constrained, metal/polymer, cemented |
| KWY | Prosthesis, hip, hemi-, femoral, metal/polymer, cemented or uncemented |
| LWJ | Prosthesis, hip, semi-constrained, metal/polymer, uncemented |
| LZO | Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented |
| MAY | Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous cemented, osteophilic finish |
| MBL | Prosthesis, hip, semi-constrained, uncemented, metal/polymer, porous |
| KWZ | Prosthesis, hip, constrained, cemented or uncemented, metal/polymer |
FDA Premarket Submission
| FDA Premarket Submission Number [?] | Supplement Number [?] |
|---|---|
| Premarket Submission Number Not Available/Not Released | |
Sterilization
Storage and Handling
[?]| Storage and Handling |
|---|
| No storage/handling found |
Clinically Relevant Size
[?]| Size Type Text |
|---|
| Device Size Text, specify: Offset: 15.0 Millimeter |
| Outer Diameter: 28.0 Millimeter |
Device Record Status
7a1f56d3-3f65-42b8-a61a-fb0c8442a1f4
April 06, 2020
3
September 24, 2015
April 06, 2020
3
September 24, 2015
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]| Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
|---|---|---|---|---|---|
| No Package DIs found | |||||
Secondary DI
[?]| Issuing Agency [?] | Secondary DI Number |
|---|---|
| No Secondary DIs found | |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]