DEVICE: INSTRUMENT (07613327178371)

Download: XML | JSON

Device Identifier (DI) Information

INSTRUMENT
0581-1-443
0581-1-443
Howmedica Osteonics Corp.
07613327178371
GS1
1
EXETER TRIAL STEM
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN Names and Definitions: © Copyright GMDN Agency 2015. Reproduced with Permission from the GMDN Agency.

GMDN Preferred Term Name GMDN Definition
Femoral stem trial prosthesis A copy of a final femoral stem prosthesis designed to be used for trial reductions during hip arthroplasty to judge the correct offset, leg-length, and range of motion of the final femoral prosthesis to be implanted. It is one of a set of trial hip prostheses that match the different anatomical structures of the hip joint, and is used in conjunction with femoral head trial prostheses. It is typically made of metal or polymer material and includes trial stems and trial necks. This is a reusable device intended to be sterilized prior to use.
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
LPH PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED
MEH Prosthesis, hip, semi-constrained, uncemented, metal/polymer, non-porous, calicum-phosphate
KWY Prosthesis, hip, hemi-, femoral, metal/polymer, cemented or uncemented
KWZ Prosthesis, hip, constrained, cemented or uncemented, metal/polymer
MBL Prosthesis, hip, semi-constrained, uncemented, metal/polymer, porous
HWC Screw, fixation, bone
LZO Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented
JDI Prosthesis, hip, semi-constrained, metal/polymer, cemented
LWJ Prosthesis, hip, semi-constrained, metal/polymer, uncemented
MAY Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous cemented, osteophilic finish
KWL Prosthesis, hip, hemi-, femoral, metal
CLOSE

Sterilization

No
Yes
Sterilization Method [?]
Moist Heat or Steam Sterilization
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Device Size Text, specify: Taper Connection: V40?
Device Size Text, specify: Offset: 44.0 Millimeter
Device Size Text, specify: Size: 3
CLOSE

Device Status

In Commercial Distribution
September 24, 2016

CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
No
No
No CLOSE

Customer Contact

[?]
No Customer Contact currently defined
CLOSE