DEVICE: INSTRUMENT (07613327180138)

Download: XML | JSON

Device Identifier (DI) Information

INSTRUMENT
1100-1330S
1100-1330S
Howmedica Osteonics Corp.
07613327180138
GS1
1
CUTTING EDGE ADVANTAGE / SECUR-FIT MAX DEGREE TRIAL NECK
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN Names and Definitions: © Copyright GMDN Agency 2015. Reproduced with Permission from the GMDN Agency.

GMDN Preferred Term Name GMDN Definition
Femoral stem trial prosthesis A copy of a final femoral stem prosthesis designed to be used for trial reductions during hip arthroplasty to judge the correct offset, leg-length, and range of motion of the final femoral prosthesis to be implanted. It is one of a set of trial hip prostheses that match the different anatomical structures of the hip joint, and is used in conjunction with femoral head trial prostheses. It is typically made of metal or polymer material and includes trial stems and trial necks. This is a reusable device intended to be sterilized prior to use.
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
MEH Prosthesis, hip, semi-constrained, uncemented, metal/polymer, non-porous, calicum-phosphate
LZO Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented
MBL Prosthesis, hip, semi-constrained, uncemented, metal/polymer, porous
LWJ Prosthesis, hip, semi-constrained, metal/polymer, uncemented
JDI Prosthesis, hip, semi-constrained, metal/polymer, cemented
HWC Screw, fixation, bone
KWY Prosthesis, hip, hemi-, femoral, metal/polymer, cemented or uncemented
KWL Prosthesis, hip, hemi-, femoral, metal
MAY Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous cemented, osteophilic finish
LPH PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED
KWZ Prosthesis, hip, constrained, cemented or uncemented, metal/polymer
CLOSE

Sterilization

No
Yes
Sterilization Method [?]
Moist Heat or Steam Sterilization
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Device Size Text, specify: Taper Connection: C-TPR
Length: 30.0 Millimeter
Device Size Text, specify: Degree: 132.0 Degree
CLOSE

Device Status

In Commercial Distribution
September 24, 2016

CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
No
No
No CLOSE

Customer Contact

[?]
No Customer Contact currently defined
CLOSE