DEVICE: Sonopet iQ (07613327364675)

Device Identifier (DI) Information

Sonopet iQ
5500050000
In Commercial Distribution
5500-050-000
STRYKER CORPORATION
07613327364675
GS1

1
196548481 *Terms of Use
Ultrasonic Aspirator Console
CLOSE

Device Characteristics

MR Unsafe
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
36273 Ultrasonic surgical system generator
An electrically-powered component of an ultrasonic surgical system intended to generate a high frequency electrical current that is converted, typically within a handpiece, into an ultrasonic oscillation to fragment hard and/or soft tissue cells upon contact with a vibrating tip. It is used in a variety of surgical disciplines (e.g., arthroscopy, gynaecology, neurosurgery, dental/craniomaxillofacial reconstructive surgery); it is not dedicated to dental applications. It provides the controls and monitoring functions for the system during the procedure, and typically regulates energy to the system via a foot-switch; integrated suction/aspiration function may be included.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
LFL Instrument, ultrasonic surgical
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Humidity: between 10 and 75 Percent (%) Relative Humidity
Storage Environment Atmospheric Pressure: between 50 and 106 KiloPascal
Handling Environment Atmospheric Pressure: between 70 and 106 KiloPascal
Handling Environment Humidity: between 10 and 85 Percent (%) Relative Humidity
Storage Environment Temperature: between -20 and 40 Degrees Celsius
Handling Environment Temperature: between 10 and 27 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

b81a53f3-a489-4225-9fc4-5eae0718c2e3
February 22, 2022
2
May 07, 2019
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
No
No CLOSE

Customer Contact

[?]
+0018002533210
Inst.Stryker.cs@Stryker.com
CLOSE