DEVICE: AVAflex (07613327374551)
Device Identifier (DI) Information
AVAflex
1031130000
In Commercial Distribution
1031130000
STRYKER CORPORATION
1031130000
In Commercial Distribution
1031130000
STRYKER CORPORATION
11 gauge 30mm AVAflex Vertebral Balloon System
Device Characteristics
| Labeling does not contain MRI Safety Information | |
| No | |
| No | |
| Yes | |
| Yes | |
| No | |
| Yes | |
| No | |
| No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
| GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
|---|---|---|---|---|
| 47129 | Balloon kyphoplasty kit |
A collection of sterile surgical instruments and devices used for the reduction of a vertebral compression fractures (VCFs) caused by trauma, cancer, or osteoporosis during a minimally invasive procedure commonly known as balloon kyphoplasty. It typically consists of a bone access needle, an osteo introducer, an inflation syringe, and the inflatable bone tamp. This procedure involves the insertion of the balloon tamp into a patient's back to reduce a vertebral body fracture by compression of cancellous bone and/or movement of the endplates as the balloon is inflated, and filling the void created with orthopaedic cement/filler to stabilize the vertebra. This is a single-use device.
|
Active | false |
FDA Product Code
[?]| Product Code | Product Code Name |
|---|---|
| NDN | CEMENT, BONE, VERTEBROPLASTY |
FDA Premarket Submission
| FDA Premarket Submission Number [?] | Supplement Number [?] |
|---|---|
| Premarket Submission Number Not Available/Not Released | |
Sterilization
Storage and Handling
[?]| Storage and Handling |
|---|
| Storage Environment Temperature: between 12 and 25 Degrees Celsius |
| Storage Environment Humidity: between 10 and 60 Percent (%) Relative Humidity |
Clinically Relevant Size
[?]| Size Type Text |
|---|
| Device Size Text, specify: Balloon Length: 30.0 Millimeter |
| Needle Gauge: 11.0 Gauge |
Device Record Status
0e958b56-35cf-4c49-b538-0c6718a94ea5
June 04, 2018
1
May 04, 2018
June 04, 2018
1
May 04, 2018
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]| Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
|---|---|---|---|---|---|
| No Package DIs found | |||||
Secondary DI
[?]| Issuing Agency [?] | Secondary DI Number |
|---|---|
| No Secondary DIs found | |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(800)253-3210
Inst.Stryker.cs@Stryker.com
Inst.Stryker.cs@Stryker.com