DEVICE: N/A (07613327500622)

Device Identifier (DI) Information

N/A
8000-060-014
In Commercial Distribution
8000-060-014
Stryker Leibinger GmbH & Co. KG
07613327500622
GS1

1
316153956 *Terms of Use
Instrument Tracker 1
CLOSE

Device Characteristics

MR Unsafe
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
62782 Optical surgical navigation device tracking system
A mobile assembly of electrically-powered devices intended to provide a physician with optical tools to track manual surgical instruments and locate anatomical structures with respect to pre-acquired images (e.g., CT/MRI scan) or real-time data [e.g., endoscopic, ultrasound (US)]; it may be capable of creating digital 3-D patient models. It consists of a workstation with controls/display, position/movement tracking cameras (e.g., infrared), adaptors, and sensors/spatial markers designed to be attached to the patient and instruments. It is used for multiple surgical procedures (e.g., craniotomy, tumour resection) in various fields [e.g., ENT, neurosurgery, CMF surgery].
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
HAW Neurological stereotaxic Instrument
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

No
Yes
Sterilization Method [?]
Moist Heat or Steam Sterilization
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Temperature: between -10 and 50 Degrees Celsius
Handling Environment Temperature: between 10 and 30 Degrees Celsius
Handling Environment Atmospheric Pressure: between 80 and 106 KiloPascal
Special Storage Condition, Specify: KEEP AWAY FROM SUNLIGHT
Handling Environment Humidity: between 30 and 75 Percent (%) Relative Humidity
Special Storage Condition, Specify: KEEP DRY
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

ae0a4f2b-6122-461a-abbf-01ae9c4055db
April 04, 2025
3
March 23, 2023
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
No
No
No CLOSE

Customer Contact

[?]
No Customer Contact currently defined