DEVICE: OptaBlate (07613327631883)
Device Identifier (DI) Information
OptaBlate
9700010200
In Commercial Distribution
9700-010-200
STRYKER CORPORATION
9700010200
In Commercial Distribution
9700-010-200
STRYKER CORPORATION
Straight 10MM Probe Dual Kit
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
Yes | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
64233 | Percutaneous radio-frequency ablation probe, tumour-ablation, bipolar |
A semi-flexible, hand-held surgical instrument intended to be percutaneously introduced via a dedicated cannula [under computed tomography (CT), magnetic resonance imaging (MRI), or ultrasound (US) guidance] to deliver radio-frequency current in a bipolar configuration from a system generator to coagulate/ablate tissues (excluding the CNS and heart) for the treatment of tumours (e.g., in the liver); in addition to percutaneous access it might also be intended for laparoscopic and/or open surgical use. It includes distal electrodes in a bipolar arrangement and may include temperature-sensing elements; the introduction cannula may be included. This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
GEI | Electrosurgical, cutting & coagulation & accessories |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Handling Environment Humidity: between 10 and 75 Percent (%) Relative Humidity |
Storage Environment Atmospheric Pressure: between 50 and 106 KiloPascal |
Storage Environment Temperature: between -20 and 40 Degrees Celsius |
Storage Environment Humidity: between 10 and 75 Percent (%) Relative Humidity |
Handling Environment Temperature: between -20 and 40 Degrees Celsius |
Handling Environment Atmospheric Pressure: between 50 and 106 KiloPascal |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
3f185649-10c7-45d4-8d56-41ce15adc729
May 23, 2025
2
April 17, 2025
May 23, 2025
2
April 17, 2025
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(800)253-3210
inst.stryker.cs@stryker.com
inst.stryker.cs@stryker.com