DEVICE: LEICA FL800 (07630003576238)

Device Identifier (DI) Information

LEICA FL800
000000000010448748
In Commercial Distribution

Leica Microsystems (Schweiz) AG
07630003576238
GS1

1
480198725 *Terms of Use
No description.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
57883 Surgical microscope fluorescent angiography system
A non-sterile, mains electricity (AC-powered) device assembly designed for viewing intraoperative blood flow in the cerebral vascular area, in bypass grafts during coronary artery bypass graft (CABG) surgery, and during plastic and reconstructive surgery. It enables a surgical microscope to produce excitation light and resolve fluorescence from the fluorescent agent indocyanine green (ICG). Fluorescent signals depict the distribution of the infrared dye in the patient's blood vessels during the operation. The system is attached to a compatible surgical microscope and typically includes an ICG filter, a near infrared (NIR) charge-coupled device (CCD) video camera, and connecting cables.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
IZI System, x-ray, angiographic
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Handling Environment Humidity: between 10 and 100 Percent (%) Relative Humidity
Storage Environment Temperature: between -30 and 70 Degrees Celsius
Special Storage Condition, Specify:
Handling Environment Atmospheric Pressure: between 500 and 1060 millibar
Storage Environment Atmospheric Pressure: between 500 and 1060 millibar
Storage Environment Humidity: between 10 and 100 Percent (%) Relative Humidity
Handling Environment Temperature: between -30 and 70 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Device Size Text, specify:
CLOSE

Device Record Status

8687e8e9-b927-456f-9aee-9fce78829ff6
March 29, 2018
2
September 13, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
Yes
No CLOSE

Customer Contact

[?]
+1(847)8213462
adam.blunier@leica-microsystems.com
CLOSE