DEVICE: Pulsar-18 (07640130436039)
Device Identifier (DI) Information
Device Characteristics
| MR Conditional | |
| No | |
| No | |
| Yes | |
| Yes | |
| No | |
| No | |
| No | |
| No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
| GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
|---|---|---|---|---|
| 47932 | Peripheral artery stent, bare-metal |
A non-bioabsorbable tubular device intended to be implanted in a peripheral artery (excludes aorta, coronary, pulmonary, and intracranial arteries) to indefinitely maintain patency and improve luminal diameter in patients with atherosclerotic disease, or following the recanalization of a total occlusion. It may additionally be intended to be implanted in an obstructed biliary duct; it is not dedicated to carotid artery implantation, and not intended for connection with an aortic stent. It is made entirely of metal [e.g., Nitinol alloy mesh structure] and typically implanted by a dedicated instrument where it self-expands upon release or is balloon expanded.
|
Active | true |
FDA Product Code
[?]| Product Code | Product Code Name |
|---|---|
| NIP | STENT, SUPERFICIAL FEMORAL ARTERY |
FDA Premarket Submission
| FDA Premarket Submission Number [?] | Supplement Number [?] |
|---|---|
| Premarket Submission Number Not Available/Not Released | |
Sterilization
Storage and Handling
[?]| Storage and Handling |
|---|
| Handling Environment Temperature: between 10 and 30 Degrees Celsius |
| Special Storage Condition, Specify: Keep away from sunlight store in a dry location |
| Handling Environment Temperature: between 50 and 86 Degrees Fahrenheit |
Clinically Relevant Size
[?]| Size Type Text |
|---|
| Device Size Text, specify: Usable Length: 90 cm |
| Device Size Text, specify: Length: 80 mm |
| Device Size Text, specify: Diameter: 4 mm |
Device Record Status
72a96bfb-4b02-47eb-bb5b-5c9a7895fdc9
December 11, 2024
8
April 11, 2017
December 11, 2024
8
April 11, 2017
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]| Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
|---|---|---|---|---|---|
| No Package DIs found | |||||
Secondary DI
[?]| Issuing Agency [?] | Secondary DI Number |
|---|---|
| No Secondary DIs found | |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI