DEVICE: TactiSys™ (07640157990194)

Device Identifier (DI) Information

TactiSys™
PN-004400
In Commercial Distribution
PN-004400
ST. JUDE MEDICAL, INC.
07640157990194
GS1

1
149818952 *Terms of Use
Quartz Equipment
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
34972 Cardiac mapping system computer
A dedicated computer with software that is a component of a cardiac mapping system and is used to process and store electronic information/data for the interpretation of cardiac physiological parameters received from the output of connected measuring devices [e.g., body surface or intracardiac electrocardiograph (ECG) sensors/transducers]. The measurements can be compared to pre-established diagnostic criteria for parameters such as cardiac blood flow, electrical conduction, or heart chamber geometry. The device may display real-time cardiac maps in various formats (e.g., electrical propagation maps, electrical potential maps, and cardiac chamber geometry maps).
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
OAE Catheter, percutaneous, cardiac ablation, for treatment of atrial fibrillation
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Special Storage Condition, Specify: Keep Dry; Fragile, Handle with care
Storage Environment Humidity: between 15 and 95 Percent (%) Relative Humidity
Storage Environment Temperature: between -10 and 50 Degrees Celsius
Handling Environment Humidity: between 15 and 95 Percent (%) Relative Humidity
Handling Environment Temperature: between -10 and 50 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

d60caa24-f71d-47b5-aef0-0731f36f9000
June 13, 2024
8
November 03, 2014
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
Yes
No CLOSE

Customer Contact

[?]
+1(855)478-5833
customerservice@sjm.com
CLOSE