DEVICE: NA (08033003263440)

Notice: Any discrepancies with this record compared to the label?
If so, send a picture of the label to GUDIDSupport@fda.hhs.gov.

Device Identifier (DI) Information

NA
F9002SSC
In Commercial Distribution
F9002SSC
FIAB SPA
08033003263440
GS1

6
439770017 *Terms of Use
Reusable praecordial suction chest electrodes for ECG, ball diameter Ø 25mm and rubber ring diameter Ø 24mm. F9002SSC model has features that make it absolutely reliable during signal recording with all different ECG devices on the market. The metallic part is silver coated (Ag/AgCl) allowing a safe and clear signal transmission. The rings are made of rubber to improve patient’s comfort. FIAB suction chest electrodes thanks to screw and clip connections, can be tapped to all ECG devices and monitors with patient cables which have plug or snap connections, 4mm hole with screw and snap.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
Yes
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
42489 Electrocardiographic electrode, reusable
A noninvasive electrical conductor designed to conduct electrical signals, generated by a patient's heart, from the skin surface to an electrocardiograph (ECG) monitoring device, via an ECG lead wire (not included). It is typically a disk-like electrode that is affixed to the skin with a special adhesive, or adhesive tape, and a conductive gel (some are pre-gelled), or using a suction mechanism; alternatively, some types may be designed to be attached to hand-held heart rate meters. Electrocardiography (ECG) is usually performed using a set of electrodes (e.g., 12) connected to appropriate leads and cables. This is a reusable device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
DRX Electrode, Electrocardiograph
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
Yes CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Temperature: between 0 and 50 Degrees Celsius
Storage Environment Atmospheric Pressure: between 20 and 80 Percent (%) Relative Humidity
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

65b3b1a9-aa17-49d6-8c62-64efd1066b11
August 28, 2020
2
June 13, 2020
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: 78033003263449 CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
+39 0558497943
quality@fiab.it
CLOSE